CATEGORY 5 4x2x24 AWG STP
 
CABLE TYPE :

CATEGORY 5 4x2x24 AWG STP to

SPECIFICATION :

ANSI/TIA/EIA-568-B.2 and IEC -61156-5 (for IEC CENELEC EN 50,288 to 3 S-90-661: 1997

FIELD OF USE :

This data communication systems, analog and diMbit kullanılır.Çiftlerin AL-PES and protects th
, 51mm electrolytic copper conductor, polyolefin shield an individual basis Couples ekranlanır on

BUILDING :

of four pairs of shielded twisted wire is created. diameter 6.4mm Cable Weight 58.0 kg / km Stan
1000mt'lik reel

 

1 - Impedance

:

1-100 MHz 100 Ohm ± 6%

2 - Effective Capacity

:

Max. 56 nf / km

3 - Conductor Resistance

:

Max. 94 W / km

4 - Resistance Unbalance

:

Max. % 2

5 - Insulation Resistance

:

5000 MKM (500 VDC)

6 - Test Voltage

:

Max. 1200 V

7 - Operating Voltage

:

Max. 250V

8 - Operating Temperature

:

+60 0C -20 0C

9 - Min. Bending Radius

:

8xD (Cable Radius)

10-Tensile Strength

:

Max.50 N/mm2

 

Frequency

(MHz)

Insertion Loss Max. (dB/100m)

Near-End Crosstalk (NEXT) LossMin. (dB)

PSNear-End Crosstalk (NEXT PS) LossMin. (DB)

Equal Level Far-End Crosstalk (ELFEXT) Min.(DB/100m)

PS Equal Level Far-End Crosstalk (PSELFEXT) Min.(DB/100m)

Structural Return Loss (SRL) Min. (DB)

0.772

1.8

67.0

64th

66.0

63.8

-

1.0

2.0

65.3

62.3

63.8

60.8

23.0

4.0

4.1

56.3

53.3

51.8

48.8

23.0

8.0

5.8

51.8

48.8

45.7

42.7

23.0

10.0

6.5

50.3

47.3

43.8

40.8

23.0

16.0

8.2

47.2

44.2

39.7

36.7

23.0

20.0

9.3

45.8

42.8

37.8

34.8

23.0

25.0

10.4

44.3

41.3

35.8

32.8

22.0

31.25

11.7

42.9

39.9

33.9

30.9

21.0

62.5

17.0

38.4

35.4

27.9

24.9

18.0

100

22.0

35.3

32.3

23.8

20.8

16.0

 


CATEGORY 5 e FTP 4x2x24 AWG
 
CABLE TYPE :

CATEGORY 5 e FTP 4x2x24 AWG

SPECIFICATION :

ANSI / TIA / EIA - 568 - B: 2 and IEC - 61156- to category 5 e CENELEC EN 50288 - 3 and IE

FIELD OF USE :

This data communication systems, analog and diMbit used.
Polyolefin 0.51 mm electrolytic copper conducto essence of a combination of couples formed by bBUILDING :which does not contain moisture. AL-PES foil 0. screen Grey PVC outer sheath (RAL 7032) Cabl kg / km Standard Packing: 100 m coil, 305 m pa

 

1 - Impedance

:

1-100 MHz 100 Ohm ± 6%

2 - Effective Capacity

:

Max. 56 nf / km

3 - Conductor Resistance

:

Max. 94 W / km

4 - Resistance Unbalance

:

Max. % 2

5 - Insulation Resistance

:

5000 MKM (500 VDC)

6 - Test Voltage

:

Max. 1200 V

7 - Operating Voltage

:

Max. 250V

8 - Operating Temperature

:

+60 0C -20 0C

9 - Min. Bending Radius

:

8xD (Cable Radius)

10-Tensile Strength

:

Max.50 N/mm2

 

Frequency

(MHz)

Insertion Loss Max. (dB/100m)

Near-End Crosstalk (NEXT) LossMin. (dB)

PSNear-End Crosstalk (NEXT PS) LossMin. (DB)

Equal Level Far-End Crosstalk (ELFEXT) Min.(DB/100m)

PS Equal Level Far-End Crosstalk (PSELFEXT) Min.(DB/100m)

Structural Return Loss (SRL) Min. (DB)

0.772

1.8

67.0

64th

66.0

63.8

-

1.0

2.0

65.3

62.3

63.8

60.8

23.0

4.0

4.1

56.3

53.3

51.8

48.8

23.0

8.0

5.8

51.8

48.8

45.7

42.7

23.0

10.0

6.5

50.3

47.3

43.8

40.8

23.0

16.0

8.2

47.2

44.2

39.7

36.7

23.0

20.0

9.3

45.8

42.8

37.8

34.8

23.0

25.0

10.4

44.3

41.3

35.8

32.8

22.0

31.25

11.7

42.9

39.9

33.9

30.9

21.0

62.5

17.0

38.4

35.4

27.9

24.9

18.0

100

22.0

35.3

32.3

23.8

20.8

16.0

 


CATEGORY 5 e S STP 4x2x24 AWG
 
CABLE TYPE :

CATEGORY 5 e S / STP 4x2x24 AWG

SPECIFICATION :

ANSI/TIA/EIA-568-B.2 and IEC -61156-5 (ISO/IEC-11801için S-90-661: According to 1997 100 Mhz

FIELD OF USE :

This data communication systems, analog and digital signal tran with tinned copper braid shield and cable essence, protect the ca Polyolefin 0.51 mm electrolytic copper conductor insulated core

BUILDING :

ekranlanır on the AL-PES. The essence of a combination of four
copper drain wire electrolytic coating to provide 85% tinned cop
external diameter Cable Weight 66.0 kg / km Standard Packing:

 

1 - Impedance

:

1-100 MHz 100 Ohm ± 6%

2 - Effective Capacity

:

Max. 56 nf / km

3 - Conductor Resistance

:

Max. 94 W / km

4 - Resistance Unbalance

:

Max. % 2

5 - Insulation Resistance

:

5000 MKM (500 VDC)

6 - Test Voltage

:

Max. 1200 V

7 - Operating Voltage

:

Max. 250V

8 - Operating Temperature

:

+60 0C -20 0C

9 - Min. Bending Radius

:

8xD (Cable Radius)

10-Tensile Strength

:

Max.50 N/mm2

 

Frequency

(MHz)

Insertion Loss Max. (dB/100m)

Near-End Crosstalk (NEXT) LossMin. (dB)

PSNear-End Crosstalk (NEXT PS) LossMin. (DB)

Equal Level Far- End Crosstalk (ELFEXT) Min. (DB/100m)

PS Equal Level Far-End Crosstalk (PSELFEXT) Min. (DB/100m)

Structural Return Loss (SRL) Min. (DB)

0.772

1.8

67.0

64th

66.0

63.8

-

1.0

2.0

65.3

62.3

63.8

60.8

23.0

4.0

4.1

56.3

53.3

51.8

48.8

23.0

8.0

5.8

51.8

48.8

45.7

42.7

23.0

10.0

6.5

50.3

47.3

43.8

40.8

23.0

16.0

8.2

47.2

44.2

39.7

36.7

23.0

20.0

9.3

45.8

42.8

37.8

34.8

23.0

25.0

10.4

44.3

41.3

35.8

32.8

22.0

31.25

11.7

42.9

39.9

33.9

30.9

21.0

62.5

17.0

38.4

35.4

27.9

24.9

18.0

100

22.0

35.3

32.3

23.8

20.8

16.0

 


CATEGORY 5 FTP 4x2x24 AWG
 
CABLE TYPE :

CATEGORY 5 FTP 4x2x24 AWG

SPECIFICATION :

ANSI / ICEA S-80-576-ANSI/TIA/EIA 568-A

FIELD OF USE :

This data communication systems, analog and digital sign7x 0.20 mm electrolytic copper conductor,
polyolefin insulated cores twisted in pairs
twisted cable core is created in a combination of Couple contain moisture and the polyester film dielectric.

BUILDING :

7x 0.20 mm electrolytic tinned copper drain wire. AL-PES foil shield.
gray colored PVC outer sheath (RAL 7032) Cable outer diameter 5.6 mm
Cable Weight 43.0 kg / km
Standard Packing: 100 m coil, 305mt'lik parcels, 1000mt'

 

1- Impedance

:

1-100 MHz 100 Ohm ± 15%

2 - Effective Capacity

:

Max. 56 nf / km

3 - Conductor Resistance

:

Max. 88 / km

4 - Resistance Unbalance

:

Max. 3%

5 - Insulation Resistance

:

5000 M km (500 VDC)

6 - Test Voltage

:

Max. 500 V

7 - Operating Voltage

:

Max. 250V

8 - Operating Temperature

:

+60 0C -20 0C

9 - Min. Bending Radius

:

10xD (Cable radius)

10-Tensile Strength

:

Max.50 N/mm2

 

Frequency (MHz)

Recycle Loss (dB)

Weight Loss Max. (DB/100m)

Near End Crosstalk Min. (DB)

0.772

23.0

1.8

64th

1.0

23.0

2.2

62

4.0

23.0

5.2

53

8.0

23.0

6.8

48th

10.0

23.0

8.6

47th

16.0

20.0

9.2

44th

20.0

23.0

11.2

42

25.0

22.0

12.5

41

31.25

21.06

15.8

39th

62.5

12.5

22.4

35th

100

16.0

26.0

32

 


CATEGORY 5 S FTP 4x2x24 AWG
 
CABLE TYPE :

CATEGORY 5 S / FTP 4x2x24 AWG

SPECIFICATION :

ANSI / ICEA S-80-576-ANSI/TIA/EIA-568-A

FIELD OF USE :

This data communication systems, analog and digital sign7x 0.20 mm electrolytic copper conductor,
polyolefin insulated cores twisted in pairs
twisted cable core is created in a combination of Couple contain moisture and the polyester film dielectric.

BUILDING :

7x 0.20 mm electrolytic tinned copper drain wire. AL-PES foil shield.
gray colored PVC outer sheath (RAL 7032) Cable outer diameter 5.6 mm
Cable Weight 43.0 kg / km
Standard Packing: 100 m coil, 305mt'lik parcels, 1000mt'

 

1- Impedance

:

1-100 MHz 100 Ohm ± 15%

2 - Effective Capacity

:

Max. 56 nf / km

3 - Conductor Resistance

:

Max. 88 / km

4 - Resistance Unbalance

:

Max. 3%

5 - Insulation Resistance

:

5000 M km (500 VDC)

6 - Test Voltage

:

Max. 500 V

7 - Operating Voltage

:

Max. 250V

8 - Operating Temperature

:

+60 0C -20 0C

9 - Min. Bending Radius

:

10xD (Cable radius)

10-Tensile Strength

:

Max.50 N/mm2

 

Frequency (MHz)

Recycle Loss (dB)

Weight Loss Max. (DB/100m)

Near End CrosstalkMin. (DB)

0.772

23.0

1.8

64th

1.0

23.0

2.2

62

4.0

23.0

5.2

53

8.0

23.0

6.8

48th

10.0

23.0

8.6

47th

16.0

20.0

9.2

44th

20.0

23.0

11.2

42

25.0

22.0

12.5

41

31.25

21.06

15.8

39th

62.5

12.5

22.4

35th

100

16.0

26.0

32

 


CATEGORY 5 UTP 4x2x24 AWG
 
CABLE TYPE :

CATEGORY 5 UTP 4x2x24 AWG to

SPECIFICATION :

ANSI / TIA / EIA - 568 - B: 2 and IEC - 61156- to category 5 e CENELEC EN 50288 - 3 and IC

FIELD OF USE :

These data communication systems, analog andMbit used.
Polyolefin 0.51 mm electrolytic copper conducto

BUILDING :

essence of a combination of couples formed by b
(RAL 7032) Cable outer diameter 5.0 mm Cable
m coil, 305 m box, 1,000 mt spool of

 

1 - Impedance

:

1-100 MHz 100 Ohm ± 6%

2 - Effective Capacity

:

Max. 56 nf / km

3 - Conductor Resistance

:

Max. 94 W / km

4 - Resistance Unbalance

:

Max. % 2

5 - Insulation Resistance

:

5000 MKM (500 VDC)

6 - Test Voltage

:

Max. 1200 V

7 - Operating Voltage

:

Max. 250V

8 - Operating Temperature

:

+60 0C -20 0C

9 - Min. Bending Radius

:

8xD (Cable Radius)

10-Tensile Strength

:

Max.50 N/mm2

 

Frequenc y (MHz)

Insertion Loss Max. (DB/100m)

Near-End Crosstalk (NEXT) LossMin. (D B)

PSNear-End Crosstalk (NEXT PS) LossMin. (D B)

Equal Level Far-End Crosstalk (ELFEXT) Min. (DB/100m)

PS Equal Level Far-End Crosstalk (PSELFEXT) Min. (DB/100m)

Structura l Return Loss (SRL) Min. (DB)

0.772

1.8

67.0

64th

66.0

63.8

-

1.0

2.0

65.3

62.3

63.8

60.8

23.0

4.0

4.1

56.3

53.3

51.8

48.8

23.0

8.0

5.8

51.8

48.8

45.7

42.7

23.0

10.0

6.5

50.3

47.3

43.8

40.8

23.0

16.0

8.2

47.2

44.2

39.7

36.7

23.0

20.0

9.3

45.8

42.8

37.8

34.8

23.0

25.0

10.4

44.3

41.3

35.8

32.8

22.0

31.25

11.7

42.9

39.9

33.9

30.9

21.0

62.5

17.0

38.4

35.4

27.9

24.9

18.0

100

22.0

35.3

32.3

23.8

20.8

16.0

 


CATEGORY 5 UTP 4x2x24 AWG
 
CABLE TYPE :

CATEGORY 5 UTP 4x2x24 AWG

SPECIFICATION :

ANSI / ICEA S-80-576-ANSI/TIA/EIA 568-A

FIELD OF USE :

This data communication systems, analog and digital signal tranPolyolefin 7x 0.20 mm electrolytic copper conductor insulated c

BUILDING :

combination of Couple Grey PVC outer sheath (RAL 7032) CabPacking: 100 m coil, 305mt ' of parcels, 1000mt'lik reel

 

1 - Impedance

:

1-100 MHz 100 Ohm ± 15%

2 - Effective Capacity

:

Max. 56 nf / km

3 - Conductor Resistance

:

Max. 88 / km

4 - Resistance Unbalance

:

Max. 3%

5 - Insulation Resistance

:

5000 M km (500 VDC)

6 - Test Voltage

:

Max. 500 V

7 - Operating Voltage

:

Max. 250V

8 - Operating Temperature

:

+60 0C -20 0C

9 - Min. Bending Radius

:

10xD (Cable radius)

10-Tensile Strength

:

Max.50 N/mm2

 

Frequency (MHz)

Recycle Loss (dB)

Weight Loss Max. (DB/100m)

0.772

23.0

1.8

1.0

23.0

2.2

4.0

23.0

5.2

8.0

23.0

6.8

10.0

23.0

8.6

16.0

20.0

9.2

20.0

23.0

11.2

25.0

22.0

12.5

31.25

21.06

15.8

62.5

12.5

22.4

100

16.0

26.0

 


CATEGORY 6 FTP 4x2x23 AWG
 
CABLE TYPE :
CATEGORY 6 FT
SPECIFICATION :

ANSI/TIA/EIA-568-B.2-1 and IEC -61156-5 (ISO/IEC-11801i288-250M

FIELD OF USE :

This data communication systems, analog and digital0.57 mm electrolytic copper concores twisted in pairs, Couples star-shaped bend in the separ

BUILDING :

Eelectrolytic tinned coppeAL-PES foil shield, Grey PVCCable outer diameter 6.3 mm, Standard Packing: 100 m coil, 30

 

1 - Impedance

:

1-100 MHz 100 Ohm ± 6%

101-250 MHz 100 Ohm ± 20%

2 - Effective Capacity

:

Max. 56 nf / km

3 - Conductor Resistance

:

Max. 72 / km

4 - Resistance Unbalance

:

Max. % 2

5 - Insulation Resistance

:

5000 M km (500 VDC)

6 - Test Voltage

:

Max. 1200 V

7 - Operating Voltage

:

Max. 250V

8 - Operating Temperature

:

+60 0C -20 0C

9 - Min. Bending Radius

:

8xD (Cable radius)

10-Tensile Strength

:

Max.50 N/mm2

 

           

requency

(MHz)

Insertion Loss Max. (dB/100m)

Near-End Crosstalk

(NEXT) Loss Min. (dB)

PSNear-End Crosstalk (NEXT PS) Loss Min. (DB)

Equal Level Far- End Crosstalk (ELFEXT) Min. (DB/100m)

PS Equal Level Far-End Crosstalk (PSELFEXT) Min. (DB/100m)

Retu ( repor

0.772

1.8

76.0

74.0

70.0

67.0

1.0

2.0

74.3

72.3

67.8

64.8

4.0

3.8

65.3

63.3

55.8

52.8

8.0

6.3

60.8

58.8

49.7

46.7

10.0

6.0

59.3

57.3

47.8

44.8

16th

7.6

56.2

54.2

43.7

40.7

20.0

8.5

54.8

52.8

41.8

38.8

25.0

9.5

53.3

51.3

39.8

36.8

31.25

10.7

51.9

49.9

37.9

34.9

62.5

15.4

47.4

45.4

31.9

28.9

100

19.8

44.3

42.3

27.8

24.8

 


CATEGORY 6 S FTP 4x2x23 AWG
 
CABLE TYPE :

CATEGORY 6 S / F

SPECIFICATION :

ANSI/TIA/EIA-568-B.2-1 and IEC -61156-5 (ISO/IEC-11801i288-250M

FIELD OF USE :

This data communication systems, analog and digitalPolyolefin 0.57 mm electrolytic copper conductor insulated core

BUILDING :

which contain moisture and dielectric Polyester film 0.51 mm copper wire mesh screen to provide 85% off Grey PVC outer jaweight 57.0kg/km Standard Packing: 100 m

 

1- Impedance

:

1-100 MHz 100 Ohm ± 6%

101-250 MHz 100 Ohm ± 20%

2 - Effective Capacity

:

Max. 56 nf / km

3 - Conductor Resistance

:

Max. 72 / km

4 - Resistance Unbalance

:

Max. % 2

5 - Insulation Resistance

:

5000 M km (500 VDC)

6 - Test Voltage

:

Max. 1200 V

7 - Operating Voltage

:

Max. 250V

8 - Operating Temperature

:

+60 0C -20 0C

9 - Min. Bending Radius

:

8xD (Cable radius)

10-Tensile Strength

:

Max.50 N/mm2

 

             

Frequency

(MHz)

Insertion Loss Max. (dB/100m)

Near-End Crosstalk

(NEXT) Loss Min. (dB)

PSNear-End Crosstalk (NEXT PS) Loss Min. (DB)

Equal Level Far- End Crosstalk (ELFEXT) Min. (DB/100m)

PS Equal Level Far-End Crosstalk (PSELFEXT) Min. (DB/100m)

Retu ( repor

0.772

1.8

76.0

74.0

70.0

67.0

1.0

2.0

74.3

72.3

67.8

64.8

4.0

3.8

65.3

63.3

55.8

52.8

8.0

6.3

60.8

58.8

49.7

46.7

10.0

6.0

59.3

57.3

47.8

44.8

16th

7.6

56.2

54.2

43.7

40.7

20.0

8.5

54.8

52.8

41.8

38.8

25.0

9.5

53.3

51.3

39.8

36.8

31.25

10.7

51.9

49.9

37.9

34.9

62.5

15.4

47.4

45.4

31.9

28.9

100

19.8

44.3

42.3

27.8

24.8

200

29.0

39.8

37.8

21.8

18.8

250

32.8

38.3

3.3

19.8

16.8

 


CATEGORY 6 UTP 4x2x23 AWG
 
CABLE TYPE :

CATEGORY 6 UTP 4x2x23 AWG

SPECIFICATION :

ANSI/TIA/EIA-568-B.2-1 and IEC -61 156 -5 (ISO / IEC - 11 805'ye of 250 Mhz.

FIELD OF USE :

This data communication systems, analog and digital signal trans0.57 mm electrolytic copper conductor. Polyolefin insulation. Co

BUILDING

:twisted. PVC outer sheath gray color (RAL 7032) Cable outer diaPacking: 100 coil, 305 mt parcel of 1000 m ² reel

 

1 - Impedance

:

1-100 MHz 100 Ohm ± 6%

101-250 MHz 100 Ohm ± 20%

2 - Effective Capacity

:

Max. 56 nf / km

3 - Conductor Resistance

:

Max. 72 / km

4 - Resistance Unbalance

:

Max. % 2

5 - Insulation Resistance

:

5000 M km (500 VDC)

6 - Test Voltage

:

Max. 1200 V

7 - Operating Voltage

:

Max. 250V

8 - Operating Temperature

:

+60 0C -20 0C

9 - Min. Bending Radius

:

8xD (Cable radius)

10-Tensile Strength

:

Max.50 N/mm2

 

frequency

(MHz)

Insertion Loss Max. (dB/100m)

Near-End Crosstalk

(NEXT) Loss Min. (dB)

PSNear-End Crosstalk (NEXT PS) Loss Min. (DB)

Equal Level Far- End Crosstalk (ELFEXT) Min. (DB/100m)

PS Equal Level Far-End Crosstalk (PSELFEXT) Min. (DB/100m)

Return Loss

(RL)

reported. (DB)

0.772

1.8

76.0

74.0

70.0

67.0

-

1.0

2.0

74.3

72.3

67.8

64.8

20.0

4.0

3.8

65.3

63.3

55.8

52.8

23.0

8.0

6.3

60.8

58.8

49.7

46.7

24.5

10.0

6.0

59.3

57.3

47.8

44.8

25.0

16th

7.6

56.2

54.2

43.7

40.7

25th

20.0

8.5

54.8

52.8

41.8

38.8

24.3

25.0

9.5

53.3

51.3

39.8

36.8

23.6

31.25

10.7

51.9

49.9

37.9

34.9

21.5

62.5

15.4

47.4

45.4

31.9

28.9

20.1

100

19.8

44.3

42.3

27.8

24.8

18.0

200

29.0

39.8

37.8

21.8

18.8

17.3

 


RS 422
 
CABLE TYPE :

RS 422

FIELD OF USE :

Computer / printer connections between computers and elOver electrolytic tinned copper multi-stranded copper con

BUILDING :

47100) twisted in pairs, pairs twisted in layers veins solid polyester coated on one side with aluminum foil AL-PES PVC outer jacket (RAL 7032)

 

1. Operating Temperature

:

-30 ° C ... +80 ° C

2. Min. Bending Radius

:

15xD

3. Test Voltage

:

1200V

4. Operating Voltage

:

250V

5. Insulation Resistance

:

50 M m

6. Effective Capacity

:

45 nf / m

7-Conductor DC Resistance

:

Max. 88 W / m

24 AWG 0.22 mm2 RS 422

Number of cores and conductor cross section (mm2)

Cable Outer Diameter (mm)

Approximate Weight (g / m)

Standard Length (m)

0,22 * 2 * 2

6.4

60th

1000/100

0,22 * 2 * 3

7.9

79th

1000/100

0,22 * 2 * 4

8.0

89th

1000/100

0,22 * 2 * 5

8.9

105

1000/100

0,22 * 2 * 6

9.6

121

1000/100

0,22 * 2 * 7

9.6

128

1000/100

0,22 * 2 * 8

10.2

141

1000/100

0,22 * 2 * 9

10.7

156

1000/100

0,22 * 2 * 10

11.2

166

500/100

0,22 * 2 * 12

11.9

184

500/100

RS 422 20 AWG 0.5 mm2

Number of cores and conductor cross section (mm2)

Cable Outer Diameter (mm)

Approximate Weight (g / m)

Standard Length (m)

0,50 * 2 * 2

10.0

108

1000/100

0,50 * 2 * 3

10.4

130

1000/100

0,50 * 2 * 4

11.3

150

1000/100

0,50 * 2 * 5

12.3

165

1000/100

0,50 * 2 * 6

12.7

173

1000/100

0,50 * 2 * 7

12.7

195

1000/100

0,50 * 2 * 8

13.4

218

500/100

0,50 * 2 * 9

14.0

255

500/100

0,50 * 2 * 10

15.2

280

500/100

0,50 * 2 * 12

16.9

334

500/100

 


RS-232
 
CABLE TYPE :

RS-232

FIELD OF USE :

Computer / printer connections between computers and electroniOver multi-wire solid electrolytic tinned stranded copper conduc

BUILDING :

47100) twisted in pairs, pairs twisted in layers veins contain moi wire stranded solid electrolytic copper foil on one side against p shield PVC outer sheath gray (RAL 7032)

 

1. Operating Temperature

:

-20 ° C ... +70 ° C

2. Min. Bending Radius

:

10xD

3. Test Voltage

:

1200V

4. Operating Voltage

:

250V

5. Insulation Resistance

:

50 M km

6. Effective Capacity

:

100 nf / m

RS-232 24 AWG 0.22 mm2

Number of cores and conductor cross section (mm2)

Cable Outer Diameter (mm)

Approximate Weight (kg / km)

Standard Length (m)

0,22 * 2 * 2

6.2

60.0

1000/100

0,22 * 2 * 3

7.7

69.0

1000/100

0,22 * 2 * 4

7.8

86.5

1000/100

0,22 * 2 * 5

9.6

99.0

500/100

0,22 * 2 * 6

9.9

110.0

500/100

0,22 * 2 * 7

10.1

117.0

500/100

0,22 * 2 * 8

10.3

130.0

500/100

0,22 * 2 * 10

11.7

153.0

500/100

0,22 * 2 * 12

12.3

174.0

500/100

RS-232 22 AWG 0.34 mm2

Number of cores and conductor cross section (mm2)

Cable Outer Diameter (mm)

Approximate Weight (kg / km)

Standard Length (m)

0,34 * 2 * 2

8.7

88.0

1000/100

0,34 * 2 * 3

9.0

100.0

1000/100

0,34 * 2 * 4

9.7

115.0

1000/100

0,34 * 2 * 5

11.0

143.0

500/100

0,34 * 2 * 6

11.6

154.0

500/100

0,34 * 2 * 7

11.8

164.5

500/100

0,34 * 2 * 8

12.6

183.7

500/100

0,34 * 2 * 10

14.5

233.0

500/100

0,34 * 2 * 12

15.4

272.2

500/100

1RS-232 20 AWG 0.5 mm2

Number of cores and conductor cross section (mm2)

Cable Outer Diameter (mm)

Approximate Weight (kg / km)

Standard Length (m)

0,50 * 2 * 2

9.7

104.0

1000/100

0,50 * 2 * 3

10.1

125.0

1000/100

0,50 * 2 * 4

10.9

145.0

1000/100

0,50 * 2 * 5

11.8

155.0

500/100

0,50 * 2 * 6

12.1

177.0

500/100

0,50 * 2 * 7

12.3

190.0

500/100

0,50 * 2 * 8

13.0

208.0

500/100

0,50 * 2 * 10

14.7

268.0

500/100

0,50 * 2 * 12

16.5

323.0

500/100